OKA Concrete Industries Sdn. Bhd

OKA Concrete Industries Sdn. Bhd. Malaysia

Malaysia Quality System ISO9002

line.gif (53 bytes)
  Our Products 

   
Concrete Porous Pipes
    MS 525 - 1986
    B S 1194 - 1969
    High  Frequency  Vibrated

Oka Concrete Porous Pipes

OKA Concrete Porous Pipes are manufactured in
accordance with BS 1194 -1969 and MS 525 -1986.
They are manufactured by a combination of  high
frequency  vibration and extrusion method which
produces a  strong  pipe of  high  and  consistent
quality  and  are  extensively  used  for  sub - soil 
drainage to meet a variety of  needs.

     General
The use of   OKA Concrete  Porous  Pipe is  undoubtedly a  great advantage both in
efficiency and economy.   Its strength is much greater than the ordinary clay subsoil
pipe, and  
INCREASES  WITH  AGE , as it  remains unaffected by the absorption of
moisture or  by  the variations in climatic conditions.

The saving  in  trenching ,  and  the rapidity of   laying  more  than  compensate  for
higher  cost  of   the pipes ,  and  when the certainty of  correct  operations  at   little
or  no extra cost  for  maintenance is taken  into account,  the superiority of   Porous
Concrete Pipes for  Land  Drainage is uncontestable.

The unique  property of   Porous Concrete   Pipes  is  that  infiltration of  water takes
place  over   the  entire  surface  so  that ,     in fact ,   the  pipe - line enjoys  the  best
characteristics  of   the rubble drain with  the additional   advantage of a central duct
for  the  rapid  removal  of  water.    The   porosity  is  so remarkable that small drains
may be connected  to  larger  ones merely by placing  the end of  the former over the
latter without the need for  piercing  the wall  of   the main to enable  it to receive the
flow from the subsidiary.


REFERENCE TABLE
   Nominal
   Internal
   Diametrer
   mm (in)
   Effective
   Length

   mm (in)
   Wall
   Thickness

   mm (in)
   Weight
   Per Pipe

   Kg (lb)
  Rate of Infiltration
  Lit / min / m (gal/ min/ ft)
  See (a) and (b)
  BS. 1194 - 1969

100 ( 4 )
150 ( 6 )
225 ( 9 )
300 (12)

450 (18)
450 (18)
450 (18)
450 (18)

   22 ( 7/ 8 )
   25 ( 1 )
   38 ( 1½ )
   48 (1 7 / 8)

    8 ( 17 )
  12 ( 27 )
  28 ( 62 )
  42 ( 92 )

       52 ( 3½ )
     105 ( 7 )
     158 ( 10½ )
     263 ( 17½ )


a )


B. S. 1194 -1969  Porosity Test  states   that  each  selected  pipe shall  have a  rate
of  infliltration under  a  constant  head of  water two inches above  the top of  the
pipe,  of   NOT LESS  than as stated .
b )
 
The rate of   infiltration  for  porous pipes  with  non -porous  inverts shall  not be
less than one - half   the figures given above  porous pipes.

NOTE:-
1 ) Extra  Strength  Pipes are  made to order.
2 ) All  pipes available in ordinary portland cement.
3 )